{"id":35267,"date":"2025-05-20T07:12:06","date_gmt":"2025-05-20T06:12:06","guid":{"rendered":"https:\/\/www.hanitalenses.com\/?post_type=publication&#038;p=35267"},"modified":"2025-06-19T07:33:18","modified_gmt":"2025-06-19T06:33:18","slug":"dr-bianchi","status":"publish","type":"publication","link":"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/","title":{"rendered":"Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after"},"content":{"rendered":"<h3>Purpose:<\/h3>\n<p>To evaluate the safety, visual performance, and patient satisfaction of a new<br \/>\npresbyopic pseudophakic intraocular lens (IOL).<\/p>\n<h3>Methods:<\/h3>\n<p>An ambispective non-randomized study was performed in Buenos Aires, Argentina.<br \/>\nPatients included in the study underwent a programmed femtosecond laser-assisted cataract<br \/>\nsurgery (FLACS), performed between October 2020 and September 2021, with a 24-month<br \/>\nfollow-up period. The Intensity SL (Hanita Lenses) IOL was bilaterally implanted. Uncorrected<br \/>\ndistance, intermediate, and near visual acuity (UDVA\/UIVA\/UNVA, respectively), and defocus<br \/>\ncurve as well as safety parameters were measured, and patient satisfaction was evaluated<br \/>\nwith the VF-14 QOL questionnaire.<\/p>\n<h3>Results:<\/h3>\n<p>A total of 120 eyes of 60 patients (34 women and 26 men) aged 68.32\u00b18.9years<br \/>\n(54\u201385) were included. At the last follow-up, the mean monocular UDVA in eyes (n=120) with<br \/>\nan Intensity SL IOL implanted was 0.01\u00b10.07logMAR, and the corrected distance visual<br \/>\nacuity (CDVA) was \u22120.05\u00b10.06logMAR. For 120cm, mean UIVA was 0.06\u00b10.11logMAR; for<br \/>\n80cm, mean UIVA was 0.07\u00b10.07 logMAR; for 66cm, mean UIVA was 0.05\u00b10.07 logMAR<br \/>\nand for 40cm, mean UNVA was 0.09\u00b10.08 logMAR (\u22120.1 to 0.2). The mean binocular UDVA<br \/>\nin our patient group was \u22120.05\u00b10.05logMAR. Glare and halo were rare phenomena. Patient<br \/>\nsatisfaction was high. The mean score value of the VF-14 QOL questionnaire 24 months<br \/>\npostoperatively was 98.6.<\/p>\n<h3>Conclusion:<\/h3>\n<p>Patients underwent safe bilateral implantation with Intensity SL IOL, achieving<br \/>\nspectacle independence in most cases, and reported a high degree of satisfaction, refraction,<br \/>\nand vision stability 24 months after surgery.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This ambispective, non-randomized study evaluated the visual performance, safety, and patient satisfaction of the Intensity SL (Hanita Lenses) five-focus pseudophakic intraocular lens (IOL) over a 24-month period. The study included 120 eyes of 60 patients who underwent femtosecond laser-assisted bilateral cataract surgery. At two years postoperatively, patients demonstrated excellent uncorrected visual acuity across far, intermediate, and near distances (binocular UDVA \u22120.05 \u00b1 0.05 logMAR; UIVA 0.009 \u00b1 0.05; UNVA 0.04 \u00b1 0.06). Visual stability was maintained between the 6- and 24-month follow-ups. Dysphotopsias such as glare and halos were rare and mild. Patient satisfaction was remarkably high, with 95% reporting being \u00ab\u00a0very satisfied\u00a0\u00bb and 100% indicating they would choose the same IOL again. The findings support the long-term visual efficacy and quality-of-life benefits of the Intensity SL IOL.<\/p>\n","protected":false},"featured_media":0,"template":"","class_list":["post-35267","publication","type-publication","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after - Hanita Lenses<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after - Hanita Lenses\" \/>\n<meta property=\"og:description\" content=\"This ambispective, non-randomized study evaluated the visual performance, safety, and patient satisfaction of the Intensity SL (Hanita Lenses) five-focus pseudophakic intraocular lens (IOL) over a 24-month period. The study included 120 eyes of 60 patients who underwent femtosecond laser-assisted bilateral cataract surgery. At two years postoperatively, patients demonstrated excellent uncorrected visual acuity across far, intermediate, and near distances (binocular UDVA \u22120.05 \u00b1 0.05 logMAR; UIVA 0.009 \u00b1 0.05; UNVA 0.04 \u00b1 0.06). Visual stability was maintained between the 6- and 24-month follow-ups. Dysphotopsias such as glare and halos were rare and mild. Patient satisfaction was remarkably high, with 95% reporting being &quot;very satisfied&quot; and 100% indicating they would choose the same IOL again. The findings support the long-term visual efficacy and quality-of-life benefits of the Intensity SL IOL.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/\" \/>\n<meta property=\"og:site_name\" content=\"Hanita Lenses\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Hanita.Lenses\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-19T06:33:18+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/\",\"url\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/\",\"name\":\"Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after - Hanita Lenses\",\"isPartOf\":{\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/#website\"},\"datePublished\":\"2025-05-20T06:12:06+00:00\",\"dateModified\":\"2025-06-19T06:33:18+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Publication\",\"item\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/#website\",\"url\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/\",\"name\":\"Hanita Lenses\",\"description\":\"INSIGHTFUL INNOVATION\",\"publisher\":{\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/#organization\",\"name\":\"Hanita Lenses\",\"url\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.hanitalenses.com\/wp-content\/uploads\/HanitaLogo-new.svg\",\"contentUrl\":\"https:\/\/www.hanitalenses.com\/wp-content\/uploads\/HanitaLogo-new.svg\",\"width\":175,\"height\":88,\"caption\":\"Hanita Lenses\"},\"image\":{\"@id\":\"https:\/\/hanitalenses-bm.sytech.site\/fr\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/Hanita.Lenses\",\"https:\/\/www.instagram.com\/hanitalenses\/\",\"https:\/\/www.linkedin.com\/company\/25058777\/admin\/dashboard\/\",\"https:\/\/www.youtube.com\/channel\/UC2gjBuZnlUI1cXcF99aa2JA\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after - Hanita Lenses","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"fr_FR","og_type":"article","og_title":"Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after - Hanita Lenses","og_description":"This ambispective, non-randomized study evaluated the visual performance, safety, and patient satisfaction of the Intensity SL (Hanita Lenses) five-focus pseudophakic intraocular lens (IOL) over a 24-month period. The study included 120 eyes of 60 patients who underwent femtosecond laser-assisted bilateral cataract surgery. At two years postoperatively, patients demonstrated excellent uncorrected visual acuity across far, intermediate, and near distances (binocular UDVA \u22120.05 \u00b1 0.05 logMAR; UIVA 0.009 \u00b1 0.05; UNVA 0.04 \u00b1 0.06). Visual stability was maintained between the 6- and 24-month follow-ups. Dysphotopsias such as glare and halos were rare and mild. Patient satisfaction was remarkably high, with 95% reporting being \"very satisfied\" and 100% indicating they would choose the same IOL again. The findings support the long-term visual efficacy and quality-of-life benefits of the Intensity SL IOL.","og_url":"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/","og_site_name":"Hanita Lenses","article_publisher":"https:\/\/www.facebook.com\/Hanita.Lenses","article_modified_time":"2025-06-19T06:33:18+00:00","twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/","url":"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/","name":"Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after - Hanita Lenses","isPartOf":{"@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/#website"},"datePublished":"2025-05-20T06:12:06+00:00","dateModified":"2025-06-19T06:33:18+00:00","breadcrumb":{"@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/dr-bianchi\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/hanitalenses-bm.sytech.site\/fr\/"},{"@type":"ListItem","position":2,"name":"Publication","item":"https:\/\/hanitalenses-bm.sytech.site\/fr\/publication\/"},{"@type":"ListItem","position":3,"name":"Efficacy, safety, and satisfaction in patients with a functional 5-focus pseudophakic lens 2 years after"}]},{"@type":"WebSite","@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/#website","url":"https:\/\/hanitalenses-bm.sytech.site\/fr\/","name":"Hanita Lenses","description":"INSIGHTFUL INNOVATION","publisher":{"@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/hanitalenses-bm.sytech.site\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/#organization","name":"Hanita Lenses","url":"https:\/\/hanitalenses-bm.sytech.site\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.hanitalenses.com\/wp-content\/uploads\/HanitaLogo-new.svg","contentUrl":"https:\/\/www.hanitalenses.com\/wp-content\/uploads\/HanitaLogo-new.svg","width":175,"height":88,"caption":"Hanita Lenses"},"image":{"@id":"https:\/\/hanitalenses-bm.sytech.site\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/Hanita.Lenses","https:\/\/www.instagram.com\/hanitalenses\/","https:\/\/www.linkedin.com\/company\/25058777\/admin\/dashboard\/","https:\/\/www.youtube.com\/channel\/UC2gjBuZnlUI1cXcF99aa2JA"]}]}},"_links":{"self":[{"href":"https:\/\/hanitalenses-bm.sytech.site\/fr\/wp-json\/wp\/v2\/publication\/35267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hanitalenses-bm.sytech.site\/fr\/wp-json\/wp\/v2\/publication"}],"about":[{"href":"https:\/\/hanitalenses-bm.sytech.site\/fr\/wp-json\/wp\/v2\/types\/publication"}],"version-history":[{"count":0,"href":"https:\/\/hanitalenses-bm.sytech.site\/fr\/wp-json\/wp\/v2\/publication\/35267\/revisions"}],"wp:attachment":[{"href":"https:\/\/hanitalenses-bm.sytech.site\/fr\/wp-json\/wp\/v2\/media?parent=35267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}